0.1.8 • Published 11 months ago

@gladder/node-red-kostal-piko-json v0.1.8

Weekly downloads
-
License
MIT
Repository
github
Last release
11 months ago

Kostal Piko JSON Flow

Simple flow to query Kostal Piko Inverter using DxS

Supported Inverters

All Kostal Piko and Piko BA Inverters with UI Version >= 6.00 are supported. To doublecheck if your own inverter is supported do a HTTP-Request and check for a valid JSON Response:

http://{IP-Adress}}/api/dxs.json?dxsEntries=16777984

Response should provide Inverter Name and some additional stuff:

{
   "dxsEntries":[
      {
         "dxsId":16777984,
         "value":"YOUR INVERTER NAME"
      }
   ],
   "session":{
      "sessionId":0,
      "roleId":0
   },
   "status":{
      "code":0
   }
}

Setup

  • add node to flow
  • set inverter ip
  • use trigger node with any payload as input to trigger query to inverter (e.g. every 10 secs)
  • use payload in your flows

Sample Payload

{
   "INVERTER_NAME":"GladderION",
   "INVERTER_SERIALNUMBER":"90525OGT00xxx",
   "YIELD_TOTAL":32965.03125,
   "FEED_IN_STATUS":true,
   "STATUS":3,
   "HOME_CONSUMPTION_PV":434.571533,
   "HOME_CONSUMPTION_BATTERY":0,
   "HOME_CONSUMPTION_GRID":299.860962,
   "HOME_CONSUMPTION_TOTAL":43230.886719,
   "HOME_CONSUMPTION_DAY":3611.577393,
   "FEED_IN_TIME":33919,
   "AUTONOMY_DEGREE_DAY":8.606232,
   "OWN_CONSUMPTION_RATE_TOTAL":58.314556,
   "AUTONOMY_DEGREE_TOTAL":44.466846,
   "HOME_TOTAL_POWER":734.432495,
   "BATTERY_SOC":10,
   "BATTERY_ABSOLUTE_CURRENT":0,
   "BATTERY_CURRENTDIRECTION":0,
   "YIELD_DAY":222.071976,
   "AC_P_TOTAL":434.571533,
   "COSINUS_PHI": 1.01,
   "OWN_CONSUMPTION_TOTAL":19221.90972,
   "OWN_CONSUMPTION_DAY": 222.071976,
   "OWN_CONSUMPTION_RATE_DAY": 100.0,
   "INVERTER_OPERATING_STATUS": "Einspeisen (MPP)",
   "HOME_OWN_CONSUMPTION_TOTAL": 19221.90972,
   "GRID_FREQUENZY": 50.24,
   "DC_I": 1.54521,
   "DC_P": 607.154,
}

Values

  • INVERTER_NAME: Name of inverter
  • INVERTER_SERIALNUMBER: Serialnumber of inverter
  • YIELD_TOTAL: Total yield in kWh
  • FEED_IN_STATUS: Is inverter feeding into grid
  • HOME_CONSUMPTION_PV: current consumption directly from pv in W
  • HOME_CONSUMPTION_BATTERY: current consumption directly from battery in W
  • HOME_CONSUMPTION_GRID: current consumption directly from grid in W
  • HOME_CONSUMPTION_TOTAL: overall Home consumption in kWh
  • HOME_CONSUMPTION_DAY: todays overall home consomption in Wh
  • FEED_IN_TIME: overall feed-in time in minutes
  • AUTONOMY_DEGREE_DAY: todays grade of autarky in percentage
  • OWN_CONSUMPTION_RATE_TOTAL: total rate of own consumption in percentage
  • AUTONOMY_DEGREE_TOTAL: total grade of autarky in percentage
  • HOME_TOTAL_POWER: current overall consumption in W
  • BATTERY_SOC: current state of charge of battery in percentage
  • BATTERY_ABSOLUTE_CURRENT: current current (lol) of battery without direction (absolute value)
  • BATTERY_CURRENTDIRECTION: if value > 0: battery is discharging // if value <= 0: battery is charging
  • YIELD_DAY: daily yield in kWh
  • AC_P_TOTAL: current total available power of ac-side (includes any possible consumption except for battery charging since this happens on dc-side). great value to find out how much power is available for devices like washing machine etc at home. calculate like that: *available power = AC_P_TOTAL - HOME_CONSUMPTION_PV - HOME_CONSUMPTION_BATTERY
  • COSINUS_PHI: cos phi of grid
  • OWN_CONSUMPTION_TOTAL: overall own consumption in kWh
  • OWN_CONSUMPTION_DAY: own consumption of day in kWh
  • OWN_CONSUMPTION_RATE_DAY: own consumption rate in percentage
  • INVERTER_OPERATING_STATUS: current status of inverter as localized string
  • HOME_OWN_CONSUMPTION_TOTAL: total home own consumption
  • GRID_FREQUENZY: grid frequency in Hz
  • DC_I: current overall current of dc strings
  • DC_P: current overall power of dc strings

Contact

Feel free to contact me: Patrick Moldenhauer pm@smd-kiel.de. Note that this Node is in very alpha version and could be much better for sure. Anyway - this node should work quite stable and is very fast too since DxS Endpoint can be queried quite frequently without bothering inverters comm-board too much.

License

MIT

Free Software, Hell Yeah!

0.1.8

11 months ago

0.1.7

2 years ago

0.1.4

2 years ago

0.1.3

2 years ago

0.1.6

2 years ago

0.1.5

2 years ago

0.1.2

2 years ago

0.1.1

2 years ago

0.1.0

2 years ago

0.0.6

2 years ago

0.0.5

2 years ago

0.0.4

2 years ago

0.0.3

2 years ago

0.0.2