24-bit Timer/Counter type F (TCF)

Overview

The 24-bit Timer/Counter type F (TCF) offers three Counter Operation Modes up to 24-bit, with a 7 bit Prescaler and Overflow and compare match: Frequency generation, Numerical Controller Oscillator and 8-bit Pulse-Width Modulation. It has Event generation as pulse or waveform output and it allows clocking from multiple sources.

Changelog

All notable changes to this project will be documented in this file.

1.0.2 - 2024-01-22

Bug Fixes

  • CC8SCRIP-18596 :- AVR TCF - Interrupts are not enabled in the Initialize API
  • CC8SCRIP-18536 :- AVR TCF - MCC UI Has Incorrect Name For Waveform Output 0

1.0.1 - 2023-09-06

New Features

  • CC8SCRIP-17704 :- Update PLL clock source to import pll_src value

Bug Fixes

  • CC8SCRIP-16865 :- PWM Waveform Gen mode generates wrong register values at high clock divider settings

1.0.0 - 2023-07-19

New Features

  • CC8SCRIP-15397 :- TCF- Register equation does not correlate with the header macros
  • CC8SCRIP-15137 :- TCF-Remove 'High-frequency crystal oscillator' option from Clock Source
  • CC8SCRIP-15136 :- TCF-Fix 'Phase Locked Loop' clock source
  • CC8SCRIP-15135 :- TCF-Link GUI Interrupts with interrupts in Register Initialization
  • CC8SCRIP-15134 :- TCF-Remove local export interfaces. Import public one
  • CC8SCRIP-15133 :- TCF-Remove Custom Name from TCF0 PLIB.
  • CC8SCRIP-15105 :- Interrupts are not enabled in Register Initialization
  • CC8SCRIP-15102 :- Incorrect settings for 'Requested Period s'
  • CC8SCRIP-15093 :- Incorrect allocation - clock source