node-red-contrib-modbus-api v0.3.0
node-red-contrib-modbus-api
Create your own modbus-server graphically in node-red as you would create an http API. Configure modbus-in nodes for every possible address you want to supply, gather and prepare a response in the flow and conclude with a modbus-out node to transmit the respose back to the client.
A request consists of a modbus register and a modbus function code (FC)
Supported nodejs versions are 8, 10 and 12 as well as node-red in version 0.18.x - 1.x and up. Previous versions of node-red might also work, but are not tested.
Installation
To install run
npm install node-red-contrib-modbus-api --productionOmit the --production flag, in order to install the development dependencies for testing and coverage.
This node depends on modbus-serial as the main package and will install it along with it.
Usage

After a first modbus in node is placed a modbus server has to be created and assigned to it. This server will be the source for the node of any requests a client will send to the bound address and port.

The modbus in node will then spawn messages on it's node output whenever a request on the modbus server matches the configured register, command and unitID of the modbus in node.

Within the flow you may retrieve any data from within node-red. Be aware, that the default timeout for some of the modbus clients is gracefully chosen to be around 2000ms. In most cases this may be much shorter, so pay attantion to the round-trip time of you messages and request handling.
After you placed some data into the payload of your flows message you may send it to a modbus out node. Currently this node just takes care of validating the input message and invokes the modbus response. In future versions of this node it may be possible to also specify modbus response propertie like error or exception codes.
Details of Implementation
For a detailed overview of the modbus protocol see the modbus specification document (v1_1b3).
The following read and write functions are implemented:
- FC 1 Read Input Register
- FC 2 Read Descrete Value
- FC 3 Read Holding Register
- FC 4 Read Coil
- FC 5 Set Register
- FC 6 Set Coil
This is also coupled to the implementation status of the modbus-serial package.
Modbus Responses and Exceptions
There are basic exceptions provided by the node-modbus-serial package.
Implemented error codes for request/response are:
- 0x02 - invalid register
Request size
Currently it is not possible to request more than 128 registers at a time. This will cause node-red to crash. I'm on it to implement a fix in the underlying library. It will not be possible to request more than that though.
Contribution
To setup your local development environment first clone this repository and then use docker to get your node-red environment up and running like this:
sudo docker run -p 1880:1880 -v $PWD:/tmp/node-red-contrib-modbus-api:Z -d --name nodered nodered/node-red-dockerAfter you saved your changes to the code update the installation within the container with this command:
sudo docker exec -it nodered npm install /tmp/node-red-contrib-modbus-api/ && sudo docker restart noderedNote on --privileged and -u root: This could be required on linux machines with SELinux to avoid permission errors. Keep in mind that this is insecure and considered real bad practice. Alternativly configure your SELinux to allow access from the container to the local mounted volume in order to install the npm dependencies. This should be avoidable with the :Z flag behind volume definition.
Testing and Coverage-Report
First npm install for the dev dependencies. Tests, linting and code coverage are then available through:
npm test
npm run coverage
npm run lintLicense
The BSD 3-Clause License
Roadmap
- Implementation of write functions
- Automatically create a modbus server if there is none
- Hook into the
modbus-serialdebug function and get it out to node-red - Implement modbus exceptions for the
modbus outnode - Implement data type selection and validation for modbus out node