Introduction

samsung-lfd is Node module to control Samsung large format displays over LAN-TCP or RS232-serial with JS and human friendly commands. It is NOT for use with Samsung TV sets.

Main features

  • different connection modes: tcp/serial/stream
  • different schemas of connect-disconnect cycle
  • command queuing and timing management
  • events driven

Usage

const SamsungD = require('samsung-lfd');

//process commands using TCP socket
const dev = new SamsungD({name: 'sam3', host: '192.168.4.43', id: 3});
dev.emitter.on('responseFromDevice', data => console.log(data));
dev.process('power on', 'status?'); //power display on and ask for its status
/* expected response
{
  name: 'sam3',
  raw: <Buffer aa ff 03 03 41 11 01 58>,
  status: 'OK',
  req: 'power',
  value: 'on'
}
{
  name: 'sam3',
  raw: <Buffer 00 aa ff 03 09 41 00 01 14 00 22 01 00 00 84>,
  status: 'OK',
  req: 'status',
  value: {
    power: 'on',
    volume: 20,
    mute: 'off',
    input: 'HDMI1-PC',
    aspect: 1,
    NTimeNF: 0,
    FTimeNF: 0
  }
}
*/

SamsungD Object

The primary exported object is SamsungD. It extensively uses RAW object from raw-device module as its prototype. Data neccesery to process commands is in samsungd.xml file.

Constructor new SamsungD(AddressObject, OptionsObject)

  • AddressObject <Object> - required. Use only properties associated with the desired mode (serial, tcp, stream)
    • name <string> - default 'SamsungLFD'. The name is included in response object to easy identify a display
    • id <number> - default 0. NOTEs for stream mode: all displays in RS-232 chain must have unique id number. If you set id: 0xFE all displays execute commands, but no one of them return a response.
      //for serial
    • path <string> - required. Use valid serial path available in system.
    • baudRate <number> - default 9600
    • dataBits <number> - default 8
    • parity <string> - default 'none'
    • stopBits <number> - default 1
      //for tcp
    • host <string> - required. Use valid IP address of display
    • port <number> - default 1515
      //for stream
    • stream <Stream> - required. The stream must be opened read/write Node stream. This mode is used when multiple displays are chained with RS232 cables and connected to single system serial port. SamsungD object does not care about the stream. You have to maintain stream yourself (open, close, error handling).
  • OptionsObject <Object> - optional, default is {wDuration: 1000, rDuration: 1000, disconnect: true, splitter: {timeout: 700}}
    • wDuration <number> - Inter-command period ms for set commands. A time for device to process command and to prepare and send a response.
    • rDuration <number> - Inter-command period ms for read commands. A time for device to prepare and send a response.
    • disconnect <boolean|number> - Connecion cycle scheme. Use true, false or timeoutms. True means close connection when command queue is empty, false means do not close connection, number means close connection after some ms. of connection inactivity.
    • splitter <Object> Used to select one among three supported transform streams which merge incoming data chunks and split it into valid messages. Only single property from delimiter, regex, timeout can be used.
      • timeout <number> - use @serialport/parser-inter-byte-timeout with timeout. Response is completed if inter-byte time is longer then timeout. Please consider that timeout must be shorter than durations (inter-command period) and disconnect time (if disconnect use timeout scheme)

Method process(...commands)

Encode and send commands to display. You can use multiple commands in single call. Commands will be queued and executed FIFO.

Regular commands

Commands are based on Samsung Multiple Display Control (MDC) protocol. Commands are strings in human friendly form command[?] [parameter(s)]. If command needs multiple parameters, they are separated by commas. Some examples:
power off - power off the display
input HDMI1 - set active input to HDMI1
sernum? - get display serial number.
wallDef 3x3,1 - set matrix/wall mode (using internal signal scaller). This sets the display as upper left in 3x3 wall.
Not all MDC commands are supported. All supported commands with their usage are listed in samsungd.xml file.
NOTE: You can also use MDC commands which are not listed in XML file. In this case use command number, not a name. Parameters (if any) must also be numbers. For hex numbers use 0x prefix. Example: 0x85 80. This sets display max working temperature to 80oC

Internal commands

There are some internal commands which start with #. They are not sent to device, but are processed by SamsungD object itself.

  • #pause duration - append additional pause between neighboring commands as number of miliseconds.
  • #connect - force to open connection to device.
  • #close - force to close connection to device.

Event: commandForDevice

Emited when command is properly encoded and sent to device. Of course only encoded property is sent to device itself.

  • command <Object>
    • name <string> - device name
    • command <string> - a command itself, not parsed or encoded
    • encodedstr <string> - command encoded as string
    • encoded <Buffer> - command encoded as Buffer
    • duration <number> - time ms for device to process the command.

Event: responseFromDevice

Emited when device response is properly decoded.

  • response <Object>
    • name <string> - device name
    • raw <Buffer> - not decoded raw response
    • req <string|number> - request id, used to identify response. It is just a command name or command number which response is for.
    • value <string|number|Object> - decoded response value. Return type depends on command. See samsungd.xml
    • status <'OK'|'ERR'> - response status. Corresponds to Ack(A) and Nak(N) in MDC

Event: connectionData

A data which comes directly from device port "as is". Not decoded, merged or chopped by splitter. Event is not emited in stream mode.

  • dataObj <Object>
    • name <string> - device name
    • address <string> - device address as string
    • data <Buffer> - data itself

Event: connectionStatus

Emited when device connection status changes. Event is not emited in stream mode.

  • statusObj <Object>
    • name <string> - device name
    • dev <string> - obsolete, same as name
    • address <string> - device address as string
    • status <string> - connection status
    • more <string|Object> - additional status information