thing-it-node Device Plugin for Atlas Scientific metering products (e.g. pH meter).

This allows you to

  • monitor pH or flow metering,
  • define complex scenes, storyboards and timer controlled execution

by means of thing-it-node and thing-it.com, e.g. to set up Aquaponics solution.

Installation

Hardware Setup

Your thing-it-node communicate with your Atlas Scientific Device via the I2C Protocol. Because of that the Device have first to be switched manually into I2C mode. This is described in detail on every Atlas Scientific Device Datasheet. e.g. PH Probe on page 40.

Then connect your Atlas Scientific metering product to the GPIOs of your Single-Board Computer e.g. the pH probe to your Raspberry Pi Zero as follows

or for details like in the wireframe below

Note: I2C normally requires extra PullUp resistors on his data wires. On the Raspberry Pi they are already build in.

Atlas Scientific has plenty of documentation for the setup of the different probes.

Installation of NodeJS and thing-it-node

First, install node.js and thing-it-node on your Raspberry Pi following the instructions on the [thing-it-node] Wiki.

To let the Pi comunicate with the Atlas Device you have to activate the Pis I2C interface via

sudo raspi-config

Choose 8. Advanced Options and then 7. I2C.

Initialization and Start of thing-it-node

The thing-it-device-atlas-scientific Plugin is installed with thing-it-node, hence there is no need to install it separately.

The Plugin supports Autodiscovery for connected I2C devices, hence you only have to create a directory in which you intend to run the configuration, e.g.

mkdir ~/atlas-scientific-test
cd ~/atlas-scientific-test

and invoke

tin init

and then start thing-it-node via

tin run

Note, that at this point Autodiscovery would only discover distinct products such as pH meter or temperature sensor. It will not be able to distinguish between two pH meters if you set up an I2C bus as opposed to the single device setup above.

If you don't want to use Autodiscovery, you may use configurations like the sample configuration via

tin example --device atlas-scientific

If you want to pair the thing-it-node Gateway and its sample configuration with thing-it.com, invoke

tin pair --mesh Test

and enter your thing-it.com account and password. The pairing will allow you to configure and monitor your local Gateway from thing-it.com and use the Mobile App below to connect to the Gateway from everywhere.

Mobile UI

Install the thing-it Mobile App from the Apple Appstore or Google Play and set it up to connect to thing-it-node locally as described here or just connect your browser under http://localhost:3001 to check how the Mobile UI would look like.

The following screenshot shows the Node Page of the sample configuration, which just defines 3 pH Meters:

(with the above values for fish ponds, you probably regret not to have defined a thing-it-node event processor to send alerts, activate the pump or the like ...)

You can also run the calibration sequence from the thing-it Mobile App:

Open the Device Page, click Calibrate High, enter the actual pH value (after waiting a few seconds for the value to stabilize) and then repeat the procedure for Calibrate Middle and Calibrate Low.

Setting the I2C address works the same way.

Where to go from here ...

Obviously, you may set up more complex configuration, e.g. an aquaponics solution with

  • water temperature sensors,
  • water level sensors,
  • switches for pumps, feeders, shades and fans,
  • cameras to watch the fish ponds remotely etc.

Or, you want to distribute a set of sensors and correlate their historical data with wheather data and other things on thing-it.com.

You may also be interested in

0.0.19

7 years ago

0.0.18

9 years ago

0.0.17

9 years ago

0.0.15

9 years ago

0.0.14

9 years ago

0.0.12

9 years ago

0.0.11

9 years ago

0.0.10

9 years ago

0.0.9

9 years ago

0.0.8

9 years ago

0.0.7

9 years ago

0.0.6

9 years ago

0.0.5

9 years ago

0.0.4

9 years ago

0.0.3

9 years ago

0.0.2

9 years ago